APC Rack PDU 2G, Switched, ZeroU, 16 A/230V

Part# AP8958
EAN:0731304277101

APC Switched Rack PDU 2G Zero U - Power distribution strip (rack-mountable) - AC 200/208/230 V - RS-232 - input: IEC 60320 C20 - output connectors: 8 - black - for P/N: AR3106SP, SMX1000C, SMX1500RM2UC, SMX1500RM2UCNC, SMX750C, SMX750CNC, SRT5KRMXLW-

 
Out of Stock

Native product specifications. The product description originates from Cnet. Foxway Distribution accepts no responsibility for error or misinformation in product descriptions from Cnet.

Product specifications

Product Description APC Switched Rack PDU 2G Zero U - power distribution strip
Manufacturer Warranty 2-year warranty
Dimensions (WxDxH) 5.6 cm x 4.6 cm x 98.8 cm
Weight 3.2 kg
Networking RS-232
Device Type Power distribution strip - rack-mountable
Remote Management Protocol SNMP, Telnet, HTTP
Input Voltage AC 200/208/230 V
Output Voltage AC 200/208/230 V
Colour Black
Designed For P/N: AR3103SP, AR3106SP, AR9300SP, AR9300SP-R, AR9307SP, AR9307SP-R, SMT2200I-AR, SMT2200R2I-AR, SMT3000I-AR, SMT3000R2I-AR, SMX1000C, SMX1500RM2UC, SMX1500RM2UCNC, SMX1500RMNCUS, SMX1500RMUS, SMX750C, SMX750CNC, SRT1000RMXLI, SRT1000RMXLI-NC, SRT10RMXLIX806, SRT1500XLI, SRT2200XLI-KR, SRT5KRMXLW-TW
Input Connectors 1 x power IEC 60320 C20
Output connectors 1 x power IEC 60320 C19 ¦ 7 x power IEC 60320 C13

General features

Device Type Power distribution strip - rack-mountable
Colour Black

Ports

Interfaces 1 x management

Warranty

Service & Support Limited warranty - 2 years

Network

Remote Management Interface RS-232
Remote Management Protocol SNMP, Telnet, HTTP

Compliance

Cables Included Power cable ¦ Serial cable - external
Rack Mounting Kit Included
Features LCD display
Compliant Standards UL, cUL, EN 61000-3-2, EN55022, ICES-003, VDE, VCCI Class A ITE, EN 61000-3-3, EN55024, RoHS, FCC Part 15 A, PSE Mark, REACH

HDD / SSD tolerance

Min Operating Temperature -5 °C
Max Operating Temperature 45 °C
Humidity Range Operating 5 - 95%

Capacity

Input Voltage AC 200/208/230 V
Input Voltage Range AC 100 - 240 V
Frequency Required 50/60 Hz
Input Connectors 1 x power IEC 60320 C20
Power Output Connectors Details 1 x power IEC 60320 C19 ¦ 7 x power IEC 60320 C13
Output Voltage AC 200/208/230 V
Max Electric Current 16 A

Physical dimensions

Width 5.6 cm
Depth 4.6 cm
Height 98.8 cm
Weight 3.2 kg

Shipping dimensions

Shipping Width 16.5 cm
Shipping Depth 11.4 cm
Shipping Height 113 cm
Shipping Weight 4.8 kg

Compatible with

Designed For P/N: AP6221CH, AR2200, AR2280, AR2487G, AR3100G, AR3100TAA, AR3100W, AR3103SP, AR3105SP, AR3105W, AR3106SP, AR3107G, AR3107SP, AR3140G, AR3140W, AR3150SP, AR3150W, AR3155SP, AR3155W, AR3157SP, AR3180G, AR3300G, AR3300SP, AR3300W, AR3305SP, AR3305W, AR3307SP, AR3307W, AR3340G, AR3340W, AR3350SP, AR3350W, AR3355SP, AR3355W, AR3357SP, AR3357X674, AR4024SP, AR4024SPX429, AR4024SPX431, AR4024SPX432, AR4038IX432, AR9300SP, AR9300SP-R, AR9307SP, AR9307SP-R, DLT3000RMI2U, NBES0302, NBPD0160A, NBPD0180, NBWL0355A, NBWL0356A, SMC1000-BR, SMC1000I-2UC, SMC1000I-BR, SMC1000IC, SMC15002U-BR, SMC1500-BR, SMC1500I2U-BR, SMC1500I-2UC, SMC1500I-BR, SMC1500IC, SMC2000I, SMC2000I-2U, SMC3000I, SMC3000RMI2U, SMT1500RM1U, SMT2200I-AR, SMT2200IC, SMT2200R2I-AR, SMT2200RM2UC, SMT2200RMI2UC, SMT2200RMI2UNC, SMT3000I2U-BR, SMT3000I-AR, SMT3000IC, SMT3000R2I-6W, SMT3000R2I-AR, SMT3000RM2UC, SMT3000RMI2UC, SMT3000RMI2UNC, SMX1000C, SMX1000US, SMX1500RM2UC, SMX1500RM2UCNC, SMX1500RMNCUS, SMX1500RMUS, SMX2000LVNCUS, SMX2000LVUS, SMX2200HVNC, SMX2200R2HVNC, SMX2200RMHV2U, SMX2200RMLVUS, SMX3000HV-BR, SMX3000HVT, SMX3000HVTUS, SMX3000LV2U-BR, SMX3000LVNCUS, SMX3000LVUS, SMX3000RMLVUS, SMX3KRMLVNCUS, SMX750C, SMX750CNC, SMX750US, SPD10KCBL, SPD20KCBL, SRT1000RMXLA, SRT1000RMXLA-NC, SRT1000RMXLI, SRT1000RMXLI-NC, SRT10KRMXLI, SRT10KRMXLT-IEC, SRT10KXLI, SRT10KXLT-IEC, SRT10RMXLIX806, SRT1500RMXLA, SRT1500RMXLA-NC, SRT1500XLI, SRT2200RMXLI, SRT2200RMXLI-NC, SRT2200XLI, SRT2200XLI-KR, SRT3000RMXLI, SRT3000RMXLI-NC, SRT3000RMXLW-IEC, SRT3000XLI, SRT3000XLW-IEC, SRT5KRMXLI, SRT5KRMXLI-6W, SRT5KRMXLIM, SRT5KRMXLT, SRT5KRMXLT-IEC, SRT5KRMXLTUS, SRT5KRMXLW-HW, SRT5KRMXLW-TW, SRT5KXLI, SRT6KRMXLI, SRT6KRMXLI-6W, SRT6KRMXLIM, SRT6KRMXLT, SRT6KRMXLT-IEC, SRT6KXLI, SRT6KXLT-IEC, SRT8KRMXLI, SRT8KRMXLT, SRT8KRMXLT-IEC, SRT8KXLI, SRT8KXLT-IEC, SUA2200ICH-45, SUA3000ICH-45, SUA3000I-IN, SURT3000XLI-ET, SURT5000XLIX438, SURTD5000XLI-ET, SYAF16KRMICH, SYAF8KRMTX424

Specifications

APC Switched Rack Power Distribution Units (PDUs) enable advanced, user-customizable power control and active monitoring. The output and input connections are ((42) C13, (6) C19 Remote outlet level controls allow power on/off functionality for power recycling to remotely reboot equipment and restrict unauthorized use of individual outlets. Power sequencing delays allow users to define the order in which to power up or down attached equipment. Avoid circuit overload during power recovery and extend uptime of critical equipment by prioritizing the load shedding. Current metering provides real-time remote monitoring of connected loads. Switched Rack PDUs include real power monitoring, a temperature/humidity sensor port, locking IEC receptacles, and low-profile circuit breakers. User-defined alarms warn of potential circuit overloads before critical IT failures occur. Users can access, configure, and control Switched Rack PDUs through secure Web, SNMP, or Telnet Interfaces and are complimented by APC Centralized Management platforms using InfraStruxure Central, Capacity Manager and Change Manager.

  • Network Management Capabilities
    Full-featured network management interfaces that provide standards-based management via Web, SNMP, and Telnet. Allows users to access, configure, and manage rack PDUs from remote locations to save valuable time. Associated with this feature is the ability to quickly and easily upgrade the firmware via network download to installed units for future product enhancements.
  • Remote Individual Outlet Control
    Remotely manage outlets so users can turn outlets off that are not in use (prevent overloads) or recycle power to locked-up equipment (minimize costly downtime and avoid travel time to equipment).
  • Alarm Thresholds
    Define alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems.
  • Local Current Monitoring Display
    The aggregate current draw per rack PDU is displayed on the unit via a digital display. The local digital display helps installers avoid overloaded circuits by providing a visible warning when the current draw is close to the maximum amperage draw of the strip.
  • Power Delays
    Allows users to configure the sequence in which power is turned on or off for each outlet. This helps avoid in-rushes at start-up, which can cause overloaded circuits and dropped loads. Sequencing also allows users to predetermine which piece of equipment is turned on first so other equipment dependent on that unit will function properly.
  • Load indicator LED
    Indicates overload and warning conditions based on the user-defined alarm thresholds. Alerts users of potential overloaded circuits.
  • Flash Upgradeable
    Quickly and easily upgrade firmware via network download for future product enhancements. Eliminates the need to replace products already installed in the field when new features are released.
  • Integrates with StruxureWare Data Center Expert
    An IT-ready, scalable access monitoring system that collects, organizes, and distributes critical alerts, surveillance video and key information, providing a unified view of complex physical infrastructure environments from anywhere on the network.
New Retail

New retail represents products we buy directly from leading IT manufacturers. We buy and sell products mainly within laptops, PCs, server/storage, monitors and tablets. DCC buys large batches of New Retail products which are resold in original packaging together with the original manufacturer warranty.

 

View product quality descriptions

 

You have last seen

PROD6107